A circuit breaker is a switching device conductive allowable electric current and turns off the power in excess of nominal value. It serves for protection against overload electrical circuits. Unipolar machine can only protect one wire.

unipolar machine

Construction and principle of operation

The Main characteristics of the switch are nominal and speed off. Unipolar machine is triggered through two mechanisms: thermal and electromagnetic release devices. First off the circuit in case of high load for a long time, and the second immediately, in case of short circuit.

The Device thermal protection is a bimetal plate. When it passes through the current above the maximum, it gradually heats up and bends, pushing the lever turns off the machine. After cooling the plate back into place, and the switch is ready for operation. To enter in working state, you should connect it manually.

The Electromagnetic device comprises a coil located inside the core. When passing through the winding short-circuit current occurs, the electromagnetic field, moving core, which disconnects the machine. While power contacts open, de-energizing the circuit. Because through them passes a large current, the arc occurs. It falls into the arcing chamber, where located parallel metal plates. With their help, arc crushed and falling apart.

The Machine is also used as a switch by manually turning the control knob.

The Use of single-pole circuit breaker

The Wiring in the apartment may be broken down into several groups. Connect a single pole of the machine is produced in the gap phase wires. He pushed on the rail, and the upper clamp is inserted the power cord. Shielded wire is connected to the lower clamp. If the wires are fastened by screws, they should be tightened with little effort.

connect SPST machine

As a rule, the upper terminals of the unipolar machines are connected to the power supply using the same brush, but from the bottom is the layout of the groups. You can install multiple backup devices.

Marking

The breakers have a standard marking that can be read from top to bottom.automatic single-pole 25A

The case of the device caused the values of its basic parameters:

  • Brand EKF;
  • Number of series - ВА47-29;
  • Feature C and nominal current on the machine single-pole - 25A;
  • Rated voltage - 230/415 V;
  • Maximum breaking currents under short circuit conditions - 4500 A;
  • Current limiting class is 3.

By brand, you can determine the manufacturer. Machines it is advisable to choose from the famous brands: Legrand, ABB, IEK, EKF, etc.

Recommended

Staff evaluation: system and methods

Staff evaluation: system and methods

Personnel Assessment allows you to identify how competent the employees involved in the enterprise, and it is the performance of their work – the most significant factor affecting the efficiency of the company. To clarify the impact of performa...

How to start your own business: important aspects.

How to start your own business: important aspects.

Many people, tired of working for someone else, are increasingly thinking about how to start your own business. Someone wants to open a salon, someone store, and someone enough and vegetable stalls. Before you throw in the pool with his head, it is i...

business activities. its essence and basic functions

Business activities. its essence and basic functions

The Entrepreneurial activity of the citizen – is undertaken at your own risk and independent activity, which aims to systematically profit through the sale of works, goods, services, use of the property. The citizen engaged in such activities, ...

The inscription on the machine 230/415 V means that the device can operate in single-phase and three-phase networks. The majority of the devices in everyday transactions have this capability.

Rated current is the magnitude of the current at which the machine will not work for a long time. With its increase of 13 %, it will turn off in an hour. The larger the value of long-flowing current, the faster the operation. The main objective of machine is to prevent overheating of wiring when connecting load. It is important that permissible for a conductor the current was more of the face value of the apparatus, and not Vice versa.

The Time-current characteristic "C" means the closing of both cut-off will happen after five-fold increase in rated current. It is suitable for lighting and most appliances. If the entrance is an automaton with such a characteristic, in the housing plate should be installed on the main input unit with the characteristic "In". This means that when all other characteristics are the same, it will work faster. Then you won't have to run to the entrance and turn on the machine there. Choosing the right device with the right feature provides the desired selectivity of activation.

The Maximum permissible breaking current shows its maximum value at which the machine is able to disconnect at least once.

Number of poles

If you select single-pole or two-pole machine, it is important where to install it. The main input housing panel should be set to dipole. This will allow you to securely de-energize the house wiring when carrying out repairs when to turn off the phase together with the neutral. When the house introduced the 2 wires, you can install the machine with a single pole. In the presence of a grounding conductor put a two pole induction machine.

single-pole or two-pole automatic

On every branch of your home network connected, single-pole machine with ouzo.

If the apartment is powered by three-phase scheme, should the main input to establish a four-pole machine.

Automatic SPST: price

Single-pole machine is cheaper among the rest in the line with a large number of poles. Domestic products you can buy for 40-50 rubles, and imported brands are already 150-200 rubles. it is Important to choose machines according to the ratio quality-price, not the one that is cheaper.automatic single-pole price

Error selecting slot machines

Choosing the circuit breakers, users tolerate some errors.

  1. Focus on the total power consumption instead of protecting the wiring from overload. The installation of a powerful machine on low transaction leads to its overheating. It is important to choose the machine according to the wire size.
  2. Are Often installed the same machines on all lines, therefore some of them are overloaded. For outlets need protection 25 a, And for lighting - A. Line 16 leading to the garage, can be heavily loaded with powerful tools. Here it is advisable to install the machine on a 32 A.
  3. Do Not choose machines for the price. It is better to buy products of renowned brands with guaranteed quality.

Conclusion

Make no mistake to choose the right a single pole machine, it is necessary to understand the markings on the housing from the front side. The characteristics of the device are selected depending on the type of connected load and cable cross sections.


Article in other languages:

PL: https://tostpost.com/pl/biznes/41626-jednobiegunowy-automat-urz-dzenie-dane-techniczne-i-funkcje-czno-ci.html

PT: https://tostpost.com/pt/neg-cios/41439-o-nico-p-lo-directa-um-dispositivo-especifica-es-t-cnicas-e-caracter-s.html

ZH: https://tostpost.com/zh/business/49376-unipolar-machine-device-specifications-and-features-connection.html






Alin Trodden - author of the article, editor
"Hi, I'm Alin Trodden. I write texts, read books, and look for impressions. And I'm not bad at telling you about it. I am always happy to participate in interesting projects."

Comments (0)

This article has no comment, be the first!

Add comment

Related News

Press for hay with their hands: a description of the device, scheme and recommendations

Press for hay with their hands: a description of the device, scheme and recommendations

the Question of winter storage of hay urgent for farmers and individuals involved in the breeding of livestock and poultry. There are some simple ways to package hay that do not require large expenditures. One of them – pres...

Line Manager: definition, managerial activities, tasks and functions

Line Manager: definition, managerial activities, tasks and functions

each organization has personnel management. They include three categories of people: artists, professionals and managers. The latter, in turn, are divided into:Functional, which are responsible for specific units, perform specific...

Mass production - what is it? Feature

Mass production - what is it? Feature

the production Process is organized in accordance with different criteria and approaches. In order to optimize their production cycles, increase financial results, companies are being very thoughtful to methods of manufacturing th...

Pharmaceuticals - what is it?

Pharmaceuticals - what is it?

the Pharmaceutical industry – an industry whose task is mass production of standardized drugs. It is a historical continuation of pharmacy. Between the two concepts, and methods of obtaining medication is a significant diffe...

How to change the card number on the

How to change the card number on the "Aliexpress" change rooms on the website and in the personal Cabinet "of Alipay"

Buying in these online stores like "Aliexpress" and "EBay" has long ceased to be a novelty for users of the world wide web. From Chinese manufacturers easier to find a product, the ratio of quality and price which will be a pleasa...

Catalytic reforming is an advanced technology with a century of history

Catalytic reforming is an advanced technology with a century of history

the Beneficial properties of the oil known to mankind since time immemorial. It is used to obtain fuel and raw materials for the production of synthetic fibers and plastics. While mankind has always sought to maximize profit from ...