The slope of the sewer: calculation and norms. The slope of the sewer at 1 meter in a private house

Date:

2019-04-24 13:20:25

Views:

772

Rating:

1Like 0Dislike

Share:

Table of contents:

To Lay a sewer pipe made of plastic, is much easier than to build the pipeline from the same plastic. Old cast iron pipes have long rusted and become clogged, and this caused thoughts about replacing them? The first thing you need to consider a few options:

  • Slope of sewer to 1 meter.
  • The Number of joints (the fewer seams the better).
  • Number of turns (the less the better).
  • Depth of the sewage pit.

Recommendations for laying sewer pipes

the Slope of sewer to 1 foot

To the sewage system to function properly, it is necessary to follow such rules:

1) to Calculate the distance and outline future Prokop under the pipe. The less joints and bends, the less chance for leaks.

2) Sockets of pipes shall be directed in the direction of flow of drains. This is done in order to avoid leaks.

3) do Not shorten or cut shaped parts.

4) do Not use cracked or damaged pipe or accessories.

5) inspect o-rings for defects.

6) Provide the slope of the sewer pipe 1 meter.

Assembly Rules

The Normal operation of the Sewerage system is impossible without the correct anchoring of all its elements. Unfortunately, plastic tubing lend themselves to the phenomenon of deformation, besides the loose parts under the weight of the earth will sink and change the angle of the stack. The slope of sewer to 1 meter in degrees is calculated using the approximate deflection at landing pipes. Also constructing a special attachment over the pipe in step 70 centimeters. The maximum slope of the pipe is equal to 15%, since the higher degree is not recommended because of frequent clogging.the slope of the sewer pipe 1 meter

To Measure the slope of sewer to 1 foot should be starting from construction and ending with a drain hole. Be sure to check the entire length for the presence of identical indications of bias.

Experts recommend to make the slope of the sewer pipe 100 at 1 meter in a private house so 5-7 inches from the start indicator (start of the pipe) to the end (the end of the sewer).

Calculations of the diameter of the tube

The value of the diameter of the sewer pipe depends on the number of units of sanitary ware connected to the system, and from such values as the slope of sewer to 1 foot. Professionals lead formula, according to which expect a certain diameter. It depends on such factors as:

Recommended

The most effective methods of seed germination

The most effective methods of seed germination

Despite the fact that the method of seedling in vegetable production is a very time consuming process, it is used by most gardeners. Planting seeds in open ground is an easy and convenient method, but it is effective only in certain climatic zones. I...

Retro-reflective paint. The scope of

Retro-reflective paint. The scope of

When the vehicle began to fill the road, their popularity began to gain reflective paint. Thanks to this paint, as drivers and pedestrians becomes much easier to avoid accidents in the dark. Purpose paint Reflective paint – paint material, whic...

How to make icon with your own hands - options izgotovleniya (simple and complex)

How to make icon with your own hands - options izgotovleniya (simple and complex)

In Soviet times, many collecting badges, emblems, pennants. To get them was not easy. And today, thanks to technology, you can make them yourself. Knowing how to make icon with your own hands, and you can make original gifts to your friends, and make...

  • Number of turns.
  • The percentage of the incline.
  • The Number of joints.
  • Number of bathroom supply.

The Formula is usually applied when laying sewage systems in large enterprises and in private homes or apartments, this is not necessary.

the slope of the sewer pipe 100 at 1 meterThe riser and the pipe connected to the sewage pit should have a diameter of 100 millimeters. But if, for example, pipe has diameter of 150 mm, and the riser needs to match this value. It is also worth noting that to connect the toilet to the drain system needs to use a pipe diameter of 100 millimeters.

The slope of the sewer (1 meter) in the apartment should be 4-5 cm from the beginning to its end, it will provide a flow rate of 0.7 m/s, the pipe diameter should be 80 mm.

Fan ventilation in sanitation

The Sewer vent is a pipe leading to the roof and connected to the sewer system. It serves to stabilize the air pressure in the system. When abrupt changes in pressure fan ventilation is the best solution.

the slope of the sewer pipe 100 at 1 meter in a private houseThe pressure drop suck the liquid from drains and other places with water congestion, thereby allowing access to the room an unpleasant smell.

In apartment blocks Central sewer pipe has no slope and are installed vertically as it enters the large amount of wastewater.

When calculating such factors as the slope of the sewer pipe 100 at 1 meter and volume of wastewater, usually guided by the pipe diameter. After calculating these values specify what to install: fan system (for large volumes) or check valve (for small volumes).

Check valve works only in one direction, namely, in the air pass in one direction only. Ideal for small pressures in the pipes when draining the valve opens and air is drawn into the pipe.

Cleaning of Sewerage systems

Cleaning – parts installed in a return pipe. Same was in Soviet cast iron systems for cleaning the blockages. This system introduced during the installation of plastic pipes - easy, convenient and practical. But eventually abandoned it because many believed that such a device looks unattractive against the background.

the Slope of sewer to 1 meter in degreesTip! The slope of the sewer 1 meter - external and internal - is calculated the same way. Trenches for pipe-laying should be smooth, so while falling asleep the ground was not sagging or cracking.

Also during the installation of a sewer install inspection hatches (audit). The distance between them is 13-16 meters. In multi-storey buildings suchthe manholes were installed every four floors.

Mounting the plastic to the cast iron sewer system

Many have no desire to change your entire sewer system, so change only the problematic parts. And at this stage are faced with joining plastic pipes to the old cast iron.

If you – a resident of a multistory building, don't forget to convince all the neighbors for a few hours to use the sewers to avoid unpleasant moments during the installation. For connection of such pipes is necessary to use fittings that have been manufactured specifically for this purpose.

Important! When connecting the Central cast-iron pipe and plastic that will adhere out of the apartment, the angle should not be 90 degrees.

Docking:

1) the Connection made by the two bends at 45 degrees.

2) there are three drainage at 30 degrees.

3) there are four allotment at 22 degrees.

In any case, the slope of the sewer at 1 meter Must be calculated individually. If the system is installed in a private home, such wiring is not required, will be selected only the larger diameter sewer pipe.

Error during installation sewage system

Many people make mistakes during installation, and the system is often clogged or not functioning. The most common mistakes:

1) is Used inside of the pipe for installation of external Sewerage system.

2) Incorrect slope of the sewers in 1 meter.

3) the Presence of burrs on the pipes after sawing.

Some advice from the experts

Tips:

1) the Laying of plastic pipes produced in the soil, which is not affected by additional load (for moving vehicles).

2) Installation of pipes are not recommended in areas of elevation (in places installed wells).

3) Carefully selected sealing gum, because they are separate from sewer pipes and may not be suitable or loosely seated.

4) For connection of pipes should I use lubrication (shampoo, detergent, soap). This will greatly facilitate the work.the Slope of sewer to 1 foot in the apartment

5) For the normal functioning of the drainage system it is recommended that the gap occurrence: for pipe 50 mm - 0,36 cm, and for 100 mm - 0,47.

6) to connect sanitary appliances using flexible hose, you need to use a special seal. Inlet diameter should match the diameter of the pipe.

That's all the tips and advice on laying the Sewerage system. To calculate the diameter or the percentage of the incline will not make you much trouble.


Article in other languages:

BE: https://tostpost.com/be/hatn-tul-nasc/32297-h-l-kanal-zacy-razl-k-normy-h-l-kanal-zacy-na-1-metr-u-pryvatnym-dome.html

DE: https://tostpost.com/de/gem-tlichkeit/31982-gef-lle-der-kanalisation-berechnung-und-normen-gef-lle-der-kanalisatio.html

ES: https://tostpost.com/es/la-comodidad-del-hogar/31837-la-pendiente-de-la-alcantarilla-c-lculo-de-la-norma-la-pendiente-de-la.html

KK: https://tostpost.com/kk/domashniy-uyut/32627-e-s-k-r-z-esepteu-zh-ne-normalary-k-lbeu-k-r-zd-1-metr-zheke-yde.html

PL: https://tostpost.com/pl/komfort-domu/33678-spadek-kanalizacji-obliczenia-i-normy-spadek-kanalizacji-na-1-metr-w-p.html

PT: https://tostpost.com/pt/o-aconchego-do-lar/33443-o-vi-s-de-saneamento-c-lculo-e-normais-o-vi-s-de-saneamento-1-medidor-.html

TR: https://tostpost.com/tr/domashniy-uyut/29053-nyarg-kanalizasyon-hesaplama-ve-d-zenlemeler-nyarg-kanalizasyon-1-metr.html

UK: https://tostpost.com/uk/domashn-y-zatishok/32839-uhil-kanal-zac-rozrahunok-normi-uhil-kanal-zac-na-1-metr-v-privatnomu-.html






Alin Trodden - author of the article, editor
"Hi, I'm Alin Trodden. I write texts, read books, and look for impressions. And I'm not bad at telling you about it. I am always happy to participate in interesting projects."

Comments (0)

This article has no comment, be the first!

Add comment

Related News

Construction of the roof: detailed instructions for the installation of metal

Construction of the roof: detailed instructions for the installation of metal

the Roof is one of the core elements protect the house from the external environment, so the accuracy of installation significantly affects the functionality of the roof in the future. Very often in our time, used roofing material...

Thermal Insulation And Soundproofing

Thermal Insulation And Soundproofing "TekhnoNikol Rockit"

Using slabs “TekhnoNikol Rockit” allows for efficient tasks, such as sound and heat insulation. Convenient packaging and size make it easy to deliver material to the construction site. Easy processing and installation ...

Bath doors: pictures, types, sizes, tips for choosing

Bath doors: pictures, types, sizes, tips for choosing

the Arrangement of baths is a responsible job. In this case there are no trifles. It is important to consider all the details to ensure that buildings were comfortable and safe. One of the important issues that need to be addresse...

Grapes Lydia - surprisingly tasty and hardy variety

Grapes Lydia - surprisingly tasty and hardy variety

a high Yielding grape Lydia is widely used for decorative purposes. His second name – pink Isabella. Homeland of the plant is North America. In our latitudes, this culture can be found in Moldova and Ukraine.Descriptionthe G...

How to grow begonia from seed? Tips

How to grow begonia from seed? Tips

Today, almost every flat you can find flowers. Botany has approximately 400 types of begonias. The variety is simply amazing. The beauty of flowering begonia in no way inferior to the roses. She will delight you with modest buds. ...

Non-conventional source of energy and its application

Non-conventional source of energy and its application

In the modern world problems. Despite the predictions of science fiction, people have been unable to beat starvation and infectious diseases to this day are a mortal threat to the life and health of living on Earth. But the main t...