One-pipe heating system, colloquially called ‘Leningrad”, from private developers is extremely popular. It is all in her economy, and also in ease of installation and operation. Especially in small country houses scheme is used single-tube heating systems with the lower bussing. About it and talk later in the article.
Performing the design of heating of a country house, you should first decide on what design – Monotube or twin-tube - will be most useful in this case. The first is easier to assemble and easier to operate. However, it works not so effectively. Used single-pipe systems are basically only in a small area of single storey buildings. Includes this design:
Is a scheme of one-trumpet system of heating with the bottom distributing (or any other) closed loop in which the movement of the coolant takes place in a circle. If desired, in a private house, you can use the option as part of the natural cycle or forced. In the latter case, the system has a circulation pump, pumping the coolant.
The heating System is closed (forced) is such an important advantage, as the possibility of significant fuel savings. A variant with natural circulation when using the Monotube design is rarely used. Mainly because of its lack of effectiveness. In this case, the coolant circulates through the pipes due to the temperature difference at the outlet and inlet of the boiler. Since passing through the perimeter of the room, water or antifreeze are cooling, extreme radiator heat may not be enough. Thus, in the back room the air will warm up much worse than in others. If the pump circulates coolant through the pipes faster and cools correspondingly smaller.
Recommended
The most effective methods of seed germination
Despite the fact that the method of seedling in vegetable production is a very time consuming process, it is used by most gardeners. Planting seeds in open ground is an easy and convenient method, but it is effective only in certain climatic zones. I...
Retro-reflective paint. The scope of
When the vehicle began to fill the road, their popularity began to gain reflective paint. Thanks to this paint, as drivers and pedestrians becomes much easier to avoid accidents in the dark. Purpose paint Reflective paint – paint material, whic...
How to make icon with your own hands - options izgotovleniya (simple and complex)
In Soviet times, many collecting badges, emblems, pennants. To get them was not easy. And today, thanks to technology, you can make them yourself. Knowing how to make icon with your own hands, and you can make original gifts to your friends, and make...
The Design of heating systems-the procedure is very important. In preparing the plan should consider all the details. So, for example, radiators may be included in circuit in various ways. Sometimes the diagonal is used a method in which the input and output pipes are located at two sides of the battery - top and bottom. Often used also side connection. In this case, the pipe joining the radiator on one side. Bottom connection involves connections with both sides, but only from the bottom. This method has both advantages and disadvantages. The advantages include easy installation and wiring capability of the pipes under the floor. The disadvantage of lower connection is considered not too high compared to other methods, the degree of heat of the batteries.
What is the scheme of one-trumpet system of heating with the bottom distributing, we understood. Now let's see how to assemble. The work on the Assembly begins:
Continue the installation of the heating system of the house installation of batteries. Attach a radiator is usually under the Windows. Placed on the walls they have so that distance from their lower edges to floor was about 10 cm, to the window sill – 8 cm to the wall – 5 see This will ensure maximum heat transfer.
In the next step installs pipes for heating. The connection of radiators usually is made through the bypass. This allows you to shut off the battery without shutting down the entire heating system. The bypass is mounted just. Actually the pipe itself passes under the radiator, the latter is attached to taken away from her connections.
Each battery installed by a standard tap and tap ‘Majewski”. The latter serves for draining off excess air when the molding is mounted on the inlet pipe directly next to the radiator. A conventional crane is used to disconnect/connect the battery.
Collecting all types of heating systems, including single tube, this element should be given maximum attention. Once the right tank will be mounted depends on the operating safety of the whole structure and its durability. He installed the system can be twoways. Conventional models are mounted so that they were above the boiler approximately 1-2 m. the Membrane options are installed near a heating apparatus. In any case, the installation is made on the return pipe.
On a feeding tube this important design element can not be set. Water temperature in this line is very high. And constant overheating can lead to premature failure of the device. So mounted pumps for heating systems on the return pipe through which the boiler draws the cooled water. To install the appliance in the bypass valves. Directly in front of him must be assigned to a special filter. The coolant in the pipes high purity is never different. Within the system can increase the sludge, to form the oxide, etc. If the filter is not used, the design will become cluttered.
After the installation of such equipment as pumps for heating, connect the boilers and a trial run of the equipment. Pipes joining the input and output pipes of the heating unit according to the instructions. Previously anywhere (closer to the boiler) is mounted. At the lowest point of the system cuts the drain valve.
The structure is a node of the heating system includes such elements as:
Typically, a security group set on the output tube. Without it to start the system in operation is impossible.
So, you now know what is a scheme of one-pipe heating system with lower wiring, and how it is mounted. After the Assembly, you can proceed to the operation of crimping. It will need a pump. With it, you should escalate to the system the water under pressure that is slightly greater than the working (private homes is usually 3-5 bar). During the operation of crimping you should carefully examine all joints, fittings, and tees for the presence of leaks. The arisen problem will need to address.
As already mentioned, the main disadvantage of these structures is the different temperature of heating radiators. In order to achieve uniform distribution of heat in all the rooms, you can use batteries with different number of partitions. However, it is much easier to make adjustment by means of mounted on radiators valves. Using near to the boiler should be smaller quantity of the heat carrier, through the far greater.
Of Course, the device of the heating system begins with the selection of the necessary parts. In one-pipe heating systems uses almost the same elements as in any other. Radiators can be:
Pipes for heating currently the most commonly used metal. However, you can install or steel, or even copper. The last option is considered the most reliable. But when choosing aluminum radiators use copper pipe in the system is impossible.
The structures with the natural circulation system should install metal or steel greater than the pump diameter. In too thin lines the movement of water is hampered. Installation of pipes in the system with natural circulation of the coolant is produced with a slight slope.
As you can see, no particularly complex scheme of one-trumpet system of heating with the bottom distributing is no different. Mounted it exactly the same as any other. The main thing - to observe the order of Assembly and do not violate any standards. In this case, the house will be warm and safe.
Article in other languages:
Alin Trodden - author of the article, editor
"Hi, I'm Alin Trodden. I write texts, read books, and look for impressions. And I'm not bad at telling you about it. I am always happy to participate in interesting projects."
Related News
Flower red Anthurium. Maintenance and care
the Original and very beautiful flower Anthurium (red) is quite capricious plant. Its contents in the home will require a lot of work and care. This plant, which came to our shores from tropical America, has a luxurious deep red f...
If there is a need to heat the house and provide it with hot water, you can choose the boiler is “Proterm" reviews, which you can read in the article. However, you must remember that installation of this equipment requi...
Heat transfer fluids for heating system. Antifreeze for heating: price
usually, before the heating season, the owners of industrial enterprises or town houses thinking about how to choose the right coolant for the heating system and carry out the calculation of its amount. When using as a coolant wat...
Anchor plates - application, types, advantages
Warmth and comfort in the house ensures not only the interior but the window. The extent to which they will be efficiently installed, depends on the duration of their operating period. At the present time for installation of windo...
Polyurethane sealant. Description. Scope
one-component polyurethane sealant, usually used when you need to staple, glue, sealing metal, ceramics, brick, concrete, etc. The mixture is a high-quality connection with a high degree of resistance to corrosion, and the moistur...
Tile for furnace heat-resistant. Revetment of furnaces and fireplaces
Home furnace can serve not only as a means of heating. She can turn into a stylish interior element, if you make the effort to do this. The same applies to home fires. Tiles for the stove should be fire resistant, to withstand hig...
Comments (0)
This article has no comment, be the first!